High degree of automation
|
P-101 high-pressure pump
|
|
Microcomputer controlled wavelength selection, microcomputer controlled temperature control, and electric refrigeration.
|
Double plunger reciprocating high-pressure pump has high-precision stable flow performance; The wear-resistant, pressure resistant, and corrosion-resistant imported sealing gasket extends the service life: the patented pulsation buffer ensures the pulsation buffering effect; Software program control to achieve gradient elution of dual pumps.
|
|
Building block structure design: innovative style and reasonable structure
|
Small pulsation, wide flow range, continuously adjustable, good flow repeatability, and easy solvent displacement.
|
|
High performance variable wavelength UV visible detector
|
Pressure monitoring and protection function, time flow rate program control.
|
|
High detection sensitivity, extremely low noise and drift.
|
Easy maintenance: The pump body is easy to clean, repair, and maintain; The plunger rod and sealing ring are easy to replace; It has a plunger rod cleaning function to avoid wear caused by the deposition of salt buffer solutions and other substances on the plunger rod.
|
|
New optical design, concave holographic grating, high stability.
|
Chromatography Workstation
|
|
Wide wavelength range, multi wavelength time program programming, full band pump stop scanning, selectable detection wavelength.
|
The fully Chinese operating interface better meets the needs of domestic users.
|
|
The data is directly output through the R232 interface.
|
Convenient and intuitive reverse control function, easily achieving control of pumps and detectors.
|
|
Long lifespan, deuterium lamp for over 2000 hours.
|
Powerful data processing capabilities enable the implementation of various quantitative algorithms.
|
|
High precision constant temperature column box
|
Super powerful spectral comparison function.
|
|
Large capacity, capable of accommodating a manual sampler and any two chromatography columns (15cm, 25cm, 30cm).
|
The curve correction function is easy to operate.
|
|
Advanced low-temperature control, suitable for low-temperature separation of biological samples, etc.
|
Automation: Automation of the entire process from collecting spectra to printing reports: Series spectra can be saved to files for easy management.
|
|
High temperature control accuracy, temperature display for working status, with over temperature alarm and automatic power-off function.
|
Record the original collected data and related information of the spectrum, following GLP standards.
|
|
Six way valve
|
You can design your own report output format.
|
|
The internationally recognized six way valve injection is easy to operate, has low noise, and accurate quantification.
|
Instrument information can be customized according to requirements.
|